Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
3.
Indian J Ophthalmol ; 69(10): 2846-2850, 2021 10.
Article in English | MEDLINE | ID: covidwho-1441256

ABSTRACT

In order to maintain manual dexterity and surgical skills, trainees are encouraged to partake in regular simulation. Current options for intraocular surgical simulation require specialist microscopic equipment which is expensive and requires access to simulation facilities. A set of core simulation exercises and basic surgical skills of performing the corneal incisions, capsulorhexis, improving the manual dexterity, and suturing were identified, discussed, and agreed among authors before designing this simulation exercise. In this paper, we propose a smartphone-based, low-cost, low-tech model with corresponding exercises for intraocular simulation that can be used at home for the above-mentioned surgical skill set. This model provides an easy, portable, and reproducible method of simulation and can serve as an adjunct to patient-facing surgical training, especially in the current pandemic, where the excess to the simulation facilities or setup of these facilities may be difficult.


Subject(s)
Clinical Competence , Microsurgery , Capsulorhexis , Humans , Neurosurgical Procedures , Sutures
4.
Br J Ophthalmol ; 105(9): 1313-1317, 2021 09.
Article in English | MEDLINE | ID: covidwho-1367419

ABSTRACT

PURPOSE: To assess whether pars plana vitrectomy (PPV) is an aerosol-generating procedure (AGP) in an ex vivo experimental model. METHODS: In this ex vivo study on 10 porcine eyes, optical particle counter was used to measure particles ≤10 µm using cumulative mode in the six in-built channels: 0.3 µm, 0.5 µm, 1 µm, 2.5 µm, 5 µm and 10 µm aerosols during PPV. Two parts of the study were as follows: (1) to assess the pre-experimental baseline aerosol count in the theatre environment where there are dynamic changes in temperature and humidity and (2) to measure aerosol generation with 23-gauge and 25-gauge set-up. For each porcine eye, five measurements were taken for each consecutive step in the experiment including pre-PPV, during PPV, fluid-air exchange (FAX) and venting using a flute with 23-gauge set-up and a chimney with 25-gauge set-up. Therefore, a total of 200 measurements were recorded. RESULTS: With 23-gauge and 25-gauge PPV, there was no significant difference in aerosol generation in all six channels comparing pre-PPV versus PPV or pre-PPV versus FAX. Venting using flute with 23-gauge PPV showed significant reduction of aerosol ≤1 µm. Air venting using chimney with 25-gauge set-up showed no significant difference in aerosol of ≤1 µm. For cumulative aerosol counts of all particles measuring ≤5 µm, compared with pre-PPV, PPV or FAX, flute venting in 23-gauge set-up showed significant reduction unlike the same comparison for chimney venting in 25-gauge set-up. CONCLUSION: PPV and its associate steps do not generate aerosols ≤10 µm with 23-gauge and 25-gauge set-ups.


Subject(s)
Aerosols/adverse effects , Endophthalmitis/etiology , Eye Infections/etiology , Microsurgery/adverse effects , Surgical Wound Infection/etiology , Vitrectomy/adverse effects , Animals , Disease Models, Animal , Eye Infections/transmission , Retrospective Studies , Surgical Wound Infection/transmission , Swine , Vitrectomy/methods
5.
J Cataract Refract Surg ; 46(10): 1448-1450, 2020 10.
Article in English | MEDLINE | ID: covidwho-920742
SELECTION OF CITATIONS
SEARCH DETAIL